NodeJS version 10 or greater and Node-RED version 1.0 or greater is required. | ||
## Usage | ||
@@ -86,2 +88,35 @@ | ||
### Notes on Logo! 8 | ||
On the newest Logo! 8.FS4 (and possibly 0BA8) Logic modules there is no need to set the Mode to TSAP any more, instead the default Rack/Slot value of 0/2 works just fine. | ||
The following table shows memory areas accessible without additional settings in the controller program: | ||
*Note: These memory areas seem to be read-only from outside the controller, as they are directly used by the function blocks listed in "Logo Block" of the table* | ||
| Logo Block | Logo VM Range | example Node-RED address | Description | | ||
|------------|---------------|---------------------------------------------------|-------------| | ||
| `I` | `1024 - 1031` | `DB1,BYTE1024` or `DB1,X1024.5` or `DB1,WORD1024` | Reads input terminals 1...8 or 6 or 1...16 | | ||
| `AI` | `1032 - 1063` | `DB1,WORD1032` | Reads analog input terminal 1. Always word sized. | | ||
| `Q` | `1064 - 1071` | `DB1,BYTE1064` or `DB1,X1064.5` or `DB1,WORD1064` | Reads output terminals 1...8 or 6 or 1...16 | | ||
| `AQ` | `1072 - 1103` | `DB1,WORD1072` | Reads analog output terminal 1. Always word sized. | | ||
| `M` | `1104 - 1117` | `DB1,BYTE1104` or `DB1,X1104.5` or `DB1,WORD1104` | Reads bit flags M1...M8 or M6 or M1...16 | | ||
| `AM` | `1118 - 1245` | `DB1,WORD1118` | Reads analog flag 1. Always word sized. | | ||
| `NI` | `1246 - 1061` | `DB1,BYTE1246` or `DB1,X1246.5` or `DB1,WORD1246` | Reads network input 1...8 or 6 or 1...16 | | ||
| `NAI` | `1262 - 1389` | `DB1,WORD1262` | Reads analog network input 1. Always word sized. | | ||
| `NQ` | `1390 - 1405` | `DB1,BYTE1390` or `DB1,X1390.5` or `DB1,WORD1390` | Reads network output 1...8 or 6 or 1...16 | | ||
| `NAQ` | `1406 - 1469` | `DB1,WORD1406` | Reads network output 1. Always word sized. | | ||
On the other hand, Logo memory areas VM 0-849 are mutable from outside the controller, but they need to be mapped into the Logo program. Without mapping, data written into these addresses will have no effect on program execution. Used VM addresses in the range mentioned above can be read/written from/into in the Logo program using the "Network" function blocks (in the function block setup use the *"Local variable memory (VM)"* option to map VMs to the function block). | ||
Some addressing examples: | ||
| Logo VM | Example Node-RED address | Description | | ||
|---------|--------------------------|-------------| | ||
| `0` | `DB1,BYTE0` | R/W access | | ||
| `1` | `DB1,X1.3` | R/W access Note: use booleans | | ||
| `2..3` | `DB1,WORD2` | R/W access | | ||
| `4..7` | `DB1,DWORD4` | R/W access | | ||
## Bugs and enhancements | ||
@@ -92,2 +127,7 @@ | ||
## Support | ||
Community support is offered on a best-effort basis via GitHub Issues. For commercial support, please contact us by sending an e-mail to [st-one@st-one.io](mailto:st-one@st-one.io). | ||
## License | ||
@@ -94,0 +134,0 @@ Copyright: (c) 2016-2020, ST-One Ltda., Guilherme Francescon Cittolin <guilherme@st-one.io> |
No v1
QualityPackage is not semver >=1. This means it is not stable and does not support ^ ranges.
Found 1 instance in 1 package
165976
1.88%2
-33.33%134
42.55%