@danielgindi/homebridge-bcp-charger
Advanced tools
Comparing version 1.0.5 to 1.0.6
@@ -104,8 +104,8 @@ "use strict"; | ||
riskFaultSensorStateCharacteristic = this.platform.Characteristic.ContactSensorState; | ||
riskFaultSensorStateOnValue = ((_d = this.config.riskFaultSensor) === null || _d === void 0 ? void 0 : _d.faultContactIsDetected) | ||
riskFaultSensorStateOnValue = ((_d = this.config.riskFaultSensor) === null || _d === void 0 ? void 0 : _d.faultContactIsDetected) === false | ||
? this.platform.Characteristic.ContactSensorState.CONTACT_NOT_DETECTED | ||
: this.platform.Characteristic.ContactSensorState.CONTACT_DETECTED; | ||
riskFaultSensorStateOffValue = ((_e = this.config.riskFaultSensor) === null || _e === void 0 ? void 0 : _e.faultContactIsDetected) === false | ||
? this.platform.Characteristic.ContactSensorState.CONTACT_DETECTED | ||
: this.platform.Characteristic.ContactSensorState.CONTACT_NOT_DETECTED; | ||
riskFaultSensorStateOffValue = ((_e = this.config.riskFaultSensor) === null || _e === void 0 ? void 0 : _e.faultContactIsDetected) | ||
? this.platform.Characteristic.ContactSensorState.CONTACT_NOT_DETECTED | ||
: this.platform.Characteristic.ContactSensorState.CONTACT_DETECTED; | ||
break; | ||
@@ -131,11 +131,12 @@ case 'leak': | ||
switch ((_f = this.config.operationFaultSensor) === null || _f === void 0 ? void 0 : _f.type) { | ||
default: | ||
case 'contact': | ||
operationFaultSensorType = this.platform.Service.ContactSensor; | ||
operationFaultSensorStateCharacteristic = this.platform.Characteristic.ContactSensorState; | ||
operationFaultSensorStateOnValue = ((_g = this.config.operationFaultSensor) === null || _g === void 0 ? void 0 : _g.faultContactIsDetected) | ||
operationFaultSensorStateOnValue = ((_g = this.config.operationFaultSensor) === null || _g === void 0 ? void 0 : _g.faultContactIsDetected) === false | ||
? this.platform.Characteristic.ContactSensorState.CONTACT_NOT_DETECTED | ||
: this.platform.Characteristic.ContactSensorState.CONTACT_DETECTED; | ||
operationFaultSensorStateOffValue = ((_h = this.config.operationFaultSensor) === null || _h === void 0 ? void 0 : _h.faultContactIsDetected) === false | ||
? this.platform.Characteristic.ContactSensorState.CONTACT_DETECTED | ||
: this.platform.Characteristic.ContactSensorState.CONTACT_NOT_DETECTED; | ||
operationFaultSensorStateOffValue = ((_h = this.config.operationFaultSensor) === null || _h === void 0 ? void 0 : _h.faultContactIsDetected) | ||
? this.platform.Characteristic.ContactSensorState.CONTACT_NOT_DETECTED | ||
: this.platform.Characteristic.ContactSensorState.CONTACT_DETECTED; | ||
break; | ||
@@ -148,3 +149,2 @@ case 'leak': | ||
break; | ||
default: | ||
case 'smoke': | ||
@@ -151,0 +151,0 @@ operationFaultSensorType = this.platform.Service.SmokeSensor; |
{ | ||
"displayName": "BCP EV Charger (Z-Box compatible)", | ||
"name": "@danielgindi/homebridge-bcp-charger", | ||
"version": "1.0.5", | ||
"version": "1.0.6", | ||
"description": "A homebridge plugin controlling the BCP EV chargers (Z-Box compatible chargers)", | ||
@@ -6,0 +6,0 @@ "license": "MIT", |