What is cluster2
NOTE: For node (<=0.6.x), use cluster2 version 0.3.1
cluster2 is a node.js (>= 0.8.x) compatible multi-process management module. This module grew out of
our needs in operationalizing node.js for ql.io at eBay. Built on
node's cluster
, cluster2 adds several safeguards and utility functions to help support real-world
production scenarios:
- Scriptable start, shutdown and stop flows
- Worker monitoring for process deaths
- Worker recycling
- Graceful shutdown
- Idle timeouts
- Validation hooks (for other tools to monitor cluster2 apps)
- Events for logging cluster activities
- Exit with error code when the port is busy to fail start scripts
- Disable monitor
- and more coming soon
Usage
Getting cluster2
npm install cluster2
Start a TCP Server
var Cluster = require('cluster2'),
net = require('net');
var server = net.createServer(function (c) {
c.on('end', function () {
console.log('server disconnected');
});
c.write('hello\r\n');
c.pipe(c);
});
var c = new Cluster({
port: 3000,
cluster: true
});
Start a HTTP Server
var Cluster = require('cluster2'),
http = require('http');
var server = http.createServer(function (req, res) {
res.writeHead(200);
res.end('hello');
});
var c = new Cluster({
port: 3000
});
c.listen(function(cb) {
cb(server);
});
Start an Express Server
var Cluster = require('cluster2'),
express = require('express');
var app = express.createServer();
app.get('/', function(req, res) {
res.send('hello');
});
var c = new Cluster({
port: 3000,
});
c.listen(function(cb) {
cb(app);
});
Stop a Server
var Cluster = require('cluster2');
var c = new Cluster();
c.stop();
Gracefully Shutdown a Server
var Cluster = require('cluster2');
var c = new Cluster();
c.shutdown();
Options
Cluster2 takes the following options.
cluster
: When true
starts a number of workers. Use false
to start the server as a single
process. Defaults to true
.pids
: A directory to write PID files for master and workers.port
: Port number for the app, defaults to 3000
.monPort
: Port number for the monitor URL, defaults to 3001
. Go to http://<localhost>:3001
to
view application logs (whatever is written to a /logs
dir), and npm dependencies.ecv
: ECV stands for "extended content verification". This is an object with the following
additional properties:
path
: A path to serve a heart beat. See below.monitor
: A URI to check before emitting a valid heart beat signalcontrol
: When true, allows clients to enable or disable the signal. See below.
validator to validate the runtime health of the app. If found unhealthy, emits a disable
noWorkers
: Defaults to os.cpus().length
.timeout
: Idle socket timeout. Automatically ends incoming sockets if found idle for this
duration. Defaults to 30
seconds.connThreshold
: When the number of connections processed exceeds this numbers, recycle the worker
process. This can help recover from slow leaks in your code or dependent modules.
Graceful Shutdown
The purpose of shutdown()
is to let the server reject taking new connections, handle all pending
requests and end the connecton so that no request dropped. In order to handling shutdown()
, the
server must handle close
events as follows.
var serving = true;
var server = http.createServer(function (req, res) {
if(!serving) {
// Be nice and send a connection: close as otherwise the client may pump more requests
// on the same connection
res.writeHead(200, {
'connection': 'close'
});
}
res.writeHead(200);
res.end('hello');
});
server.on('close', function() {
serving = false;
})
var c = new Cluster({
port: 3000,
cluster: true
});
Completion of shutdown()
does not necessarily mean that all worker processes are dead immediately.
The workers may take a while to complete processing of current requests and exit. The shutdown()
flow only guarantees that the server takes no new connections.
Cluster2 Events
Cluster2 is an EventEmitter
and emits the following events.
died
: Emitted when a worker dies. This event is also emitted during normal shutdown()
or
stop()
.forked
: Emitted when a new worker is forked.<signal>
: Emitted when a worker receives a signal (such as SIGKILL
, SIGTERM
or SIGINT
).
Here is an example that logs these events to the disk.
var Cluster = require('cluster2'),
http = require('http');
var server = http.createServer(function (req, res) {
res.writeHead(200);
res.end('hello');
});
var c = new Cluster({
cluster: true,
port: 3000
});
c.on('died', function(pid) {
console.log('Worker ' + pid + ' died');
});
c.on('forked', function(pid) {
console.log('Worker ' + pid + ' forked');
});
c.on('SIGKILL', function() {
console.log('Got SIGKILL');
});
c.on('SIGTERM', function(event) {
console.log('Got SIGTERM - shutting down');
});
c.on('SIGINT', function() {
console.log('Got SIGINT');
});
c.listen(function(cb) {
cb(server);
});
Routing Traffic
It is fairly common for proxies or load balancers deployed in front of node clusters, and those
proxies to use monitor URLs to detect the health of the cluster. Cluster2 includes a monitor
at http://<host>:<port>/ecv
. You can change this by setting the path
property when initializing
the cluster.
In case you want to take the node cluster out of rotation from the proxy/load balancer, you can do
so by setting control
to true
when initializing the cluster. At runtime, you can send a POST
request to http://<host>:<port>/ecv/disable
. Once this is done, further requests to
http://<host>:<port>/ecv
will get a network error. You can bring the cluster back to rotation by
sending a POST
request to http://<host>:<port>/ecv/enable
.
Since it will be potentially disastrous to let artibrary clients enable/disable traffic, you should
configure your proxy/load balancer to prevent external traffic to /ecv*
.
To test this, bring up an example
node examples/express/express-server.js
and send a GET
request to http://localhost:3000/ecv
and notice the response.
HTTP/1.1 200 OK
X-Powered-By: Cluster2
content-type: text/plain
since: Fri May 18 2012 09:49:32 GMT-0700 (PDT)
cache-control: no-cache
Connection: keep-alive
Transfer-Encoding: chunked
status=AVAILABLE&ServeTraffic=true&ip=127.0.0.1&hostname=somehost&port=3000&time=Fri May 18 2012 09:49:49 GMT-0700 (PDT)
To flip the monitor into a disabled state, send a POST
request to http://localhost:3000/disable
.
HTTP/1.1 204 No Content
X-Powered-By: Cluster2
since: Fri May 18 2012 09:54:25 GMT-0700 (PDT)
cache-control: no-cache
Connection: close
Subsequent GET
requests to http://localhost:3000/ecv
will return a response similar to the one
below.
HTTP/1.1 400 Bad Request
X-Powered-By: Cluster2
content-type: text/plain
since: Fri May 18 2012 09:54:25 GMT-0700 (PDT)
cache-control: no-cache
Connection: close
Transfer-Encoding: chunked
status=DISABLED&ServeTraffic=false&ip=127.0.0.1&hostname=somehost&port=3000&time=Fri May 18 2012 09:55:17 GMT-0700 (PDT)
To flip the monitor back into an enabled state, send a POST
request to http://localhost:3000/enable
.