node-alarmdecoder
Node.JS client for listening and parsing AlarmDecoder events over ser2sock
Easily control and monitor DSC and Ademco / Honeywell Vista alarm systems with a PC, HA system, PLC or embedded device.
This project was created for my own purpose: monitoring and controlling my DSC home alarm system, paired with Raspberry PI and AlarmDecoder AD2PI.
AlarmDecoder products:
https://www.alarmdecoder.com/catalog/index.php
Documentation is Work In Progress
Installation
npm install node-alarmdecoder
Usage
AlarmDecoder emits 4 events:
- 'connected' - Successfully connected to AlarmDecoder ser2sock interface
- 'disconnected' - You shall know
- 'zoneChanged' - Zone status has been changed. Scroll down to output example.
"state": 1 = movement started, door opened or there's a fire, 0 = movement stopped, door closed or no more fire, yay!
Example in case of Front Door is opened:
{
"zone": {
"name": "Front Door",
"type": "contact"
},
"state": 1
}
- 'keypadMessage' - Keypad message events / panel status bits. To be documented.
Usage example
const AlarmDecoder = require('node-alarmdecoder');
const myAlarm = new AlarmDecoder('alarmdecoder', 10000, {
'00:01': {
name: 'Front Door',
type: 'contact'
},
'00:02': {
name: 'Hallway',
type: 'motion'
},
'00:03': {
name: 'Livingroom',
type: 'motion'
},
'00:04': {
name: 'Yard door',
type: 'contact'
},
'00:05': {
name: 'Garage',
type: 'fire'
},
});
myAlarm.events.on('connected', () => console.log('connected'));
myAlarm.events.on('disconnected', () => console.log('disconnected'));
myAlarm.events.on('zoneChanged', (data) => console.log('zone Change', data));
myAlarm.events.on('keypadMessage', (data) => console.log('keypadMessage', data));
Output of example
zone Change {
zone: {
name: 'Hallway',
type: 'motion'
},
state: 1
} // movement in Hallway
keypadMessage { numeric: '000',
bits:
{ Ready: false,
'Armed Away': false,
'Armed Home': false,
'Backlight on': false,
Programming: false,
Beeps: 0,
'Zone bypassed': 0,
'AC power': true,
'Chime enabled': false,
'Alarm occured': false,
'Alarm on': false,
'Battery low': false,
'Entry delay off': false,
Fire: false,
'System issue': false,
'Watching perimeter': false,
'Error report': false,
'Device mode': 'DSC' },
message: 'Secure System Before Arming' }
zone Change {
zone: {
name: 'Hallway',
type: 'motion'
},
state: 0
} // no more movement in Hallway II
keypadMessage { numeric: '000',
bits:
{ Ready: true,
'Armed Away': false,
'Armed Home': false,
'Backlight on': false,
Programming: false,
Beeps: 0,
'Zone bypassed': 0,
'AC power': true,
'Chime enabled': false,
'Alarm occured': false,
'Alarm on': false,
'Battery low': false,
'Entry delay off': false,
Fire: false,
'System issue': false,
'Watching perimeter': false,
'Error report': false,
'Device mode': 'DSC' },
message: 'System Is Ready To Arm' }
zone Change {
zone: {
name: 'Front Door',
type: 'contact'
},
state: 1
} // front door opened