Advanced tools
wiliot-deployment-tools is a python library for accessing Wiliot's Deployment and Automation Tools. This python package includes the following CLI utilities:
wlt-config
)wlt-clibration-mgmt
)wlt-firmware
)wlt-power-mgmt
)wlt-log
)wlt-connectivity-analyzer
)wlt-gw-certificate
)wlt-power-optimization
)wlt-ble-simulator
)wlt-ble-sniffer
)pip install wiliot-deployment-tools
This package includes the following CLI Utilities:
Automatically connects to all Gateways / Bridges in the location specified, and configure them to optimal parameters.
usage: wlt-config -owner OWNER -location LOCATION [-ota] [-no_gp_zone] [-pacing_interval PACING_INTERVAL] [-ignore_bridges [IGNORE_BRIDGES [IGNORE_BRIDGES ...]]] [--expected_num_brgs EXPECTED_NUM_BRGS]
required arguments:
-owner OWNER Platform owner id
-location LOCATION Location name in Wiliot platform. If location has ' ' in name, input location wrapped with double quotes: --location "LOCATION NAME"
additional (optional) arguments:
-ota Updating FW version to latest for all devices
-no_gp_zone don't use Global pacing group by zone (all bridges will be GPG=0)
-pacing_interval PACING_INTERVAL
Pacing interval for all devices
-ignore_bridges [IGNORE_BRIDGES [IGNORE_BRIDGES ...]]
bridges to ignore in the tool - their configuration won't be changed
-expected_num_brgs EXPECTED_NUM_BRGS
Number of expected bridges in location. The tool will try to connect to all bridges (excluding those specified in ignore bridges) until reaching expected number.
example usage: wlt-config --owner wiliot --location "My Deployment" --ota_upgrade --pacing_interval 10 --ignore_bridges 1234ABCD0123
Configure Wiliot Bridge calibration mode, broadcast is optional
usage: wlt-calibration-mgmt -owner OwnerID -brg BridgeID -gw GW -mode CalibrationMode [-timeout TIMEOUT]
usage (broadcast): wlt-calibration-mgmt -owner OwnerID -gw GW -mode CalibrationMode [-timeout TIMEOUT]
required arguments:
-owner OWNER Owner ID
-brg BRG Bridge ID (required only for non broadcast)
-gw GW GW ID to configure bridge (required only for broadcast)
-mode Mode CalibrationMode on of 3 options: 0-regular, 1-no ch37, 2-ch37 on data only
optional arguments:
-timeout TIMEOUT Minutes timeout (not required, defaults to 5 minutes)
example usage: wlt-calibration-mgmt -owner wiliot -brg 0123ABCD -gw AB1234CD -mode 1
Update Wiliot Gateways and Bridges firmware version OTA.
Prints all avaliable Firmware versions for update for every GW Type
usage: wlt-firmware -owner OWNER [-beta] versions
optional arguments:
-beta show available beta versions / update to beta firmware
example usage: wlt-firmware -o wiliot versions
Run OTA Process, first updating specified GWs to latest / specified FW version. Afterwards seuqentially update each specified Bridges / all Bridges to the same Firmware version.
usage: wlt-firmware update -owner OWNER [-beta] [-version VERSION] [-gw GW [GW ...]] [-brg BRG [BRG ...]] [-all_brgs] [-ignore_bridges IGNORE_BRIDGES [IGNORE_BRIDGES ...]] [-action]
optional arguments:
-beta show available beta versions / update to beta firmware
-version VERSION Desired version. if not specified, will update to latest available version
-gw GW [GW ...] Gateways to update (multiple allowed)
-brg BRG [BRG ...] Bridges to update (multiple allowed)
-all_brgs update all bridges connected to Gateways
-ignore_bridges IGNORE_BRIDGES [IGNORE_BRIDGES ...]
bridges to ignore
-action update using action API
-force update bridge even if its already in desired version (applicable only with -action)
example usage: wlt-firmware -o wiliot update -gw GW0123 -all_brgs
Use Wiliot Bridge power management functionality
Configure Specified Bridges to work in power management configuration.
usage: wlt-power-mgmt -o OwnerID enter -brg BridgeID -sleepduration SLEEPDURATION -onduration ONDURATION [-keepalive KEEPALIVE] [-scan SCAN] [-ledoff] [-gw GW] [-timeout TIMEOUT]
required arguments:
-owner OWNER Owner ID
-brg BRG Bridge ID
optional arguments:
-sleepduration SLEEPDURATION
Sleep duration (minutes)
-onduration ONDURATION
On duration (seconds) *rounds to nearest 30 second interval*
-keepalive KEEPALIVE Keep alive period (seconds) *rounds to nearest 5 second interval* (not required, defaults to 30 seconds)
-scan SCAN Keep alive scan (milliseconds) *rounds to nearest 10 millisecond interval* (not required, defaults to 300 milliseconds)
-ledoff Configure LEDs off (on by default)
-gw GW GW ID to configure bridge (required only for broadcast mode)
-timeout TIMEOUT Minutes timeout (not required, defaults to 5 minutes)
example usage: wlt-power-mgmt -o wiliot enter -brg 0123ABCD -sleepduration 5 -onduration 60
Return specified bridges out of power management mode and into normal working mode.
usage: wlt-power-mgmt -o OwnerID exit -brg BridgeID [-gw GW] [-no_config] [-timeout TIMEOUT]
required arguments:
-owner OWNER Owner ID
-brg BRG Bridge ID
optional arguments:
-gw GW GW ID to configure bridge (not required)
-no_config If used, GW will not change to optimal configuration
-timeout TIMEOUT Minutes timeout (not required, defaults to 5 minutes)
example usage: wlt-power-mgmt -o wiliot exit -brg BridgeID
View Wiliot Gateway logs
usage: wlt-log -owner OWNER -gw GW
Log Viewer - CLI Tool to view Wiliot Gateway logs
required arguments:
-owner OWNER Owner ID
-gw GW Gateway ID
Change MQTT broker for Wiliot GWs
usage: wlt-broker-change [-h] -broker {wiliot,hivemq} -owner OWNER -gw GW [-env {prod,test,dev}] [-cloud {aws,gcp}] [-legacy]
required arguments:
-broker {wiliot,hivemq}
Broker to change to
-owner OWNER Owner ID
-gw GW Gateway ID
-env {prod,test,dev} Environment
-cloud {aws,gcp} Wiliot Cloud
-legacy Legacy Broker Change```
Check the RSSI values for GW-> Bridge transmissions (as received at the bridge) Can operate by: location, bridges or gateways Return the bridges with low connection Additional option: bridge-gw connectivity log printer (-bridge_log)
usage (connectivity check): wlt-connectivity-analyzer -owner OWNER -location Location
usage (bridge-gw conn log): wlt-connectivity-analyzer -owner OWNER -brg BRG -bridge_log
required arguments:
-owner OWNER Owner ID
-bridge_log (Only for bridge-gw conn log)
-brg BRG (Only for bridge-gw conn log)
optional arguments:
-gws GwsList List of gateways IDs to check connection to the bridges they see
-brgs BridgesList List of bridges IDs to check connection
-location Location Location name (as written in platform) to check all bridges in
For more documentation and instructions, please contact us: support@wiliot.com
Test Wiliot GWs capabilities. The GW Certificate includes different test that run sequentially to test each capability reported by the GW. To run the GW Certificate the GW needs to use a public MQTT Broker (HiveMQ):
Host: broker.hivemq.com TCP Port: 1883 Websocket Port: 8000 TLS TCP Port: 8883 TLS Websocket Port: 8884
More information can be found at https://www.mqtt-dashboard.com/.
Processes status packet sent by the GW to the MQTT Broker and validates it according to API Version.
Simulates Wiliot MEL and validates that data is uploaded correctly to the cloud.
Sends advertising packets via MQTT to GW and validates correct advertising by GW.
Increments time delays between packets to evaluate GW's capability in handling increasing packets per second within a minute.
Version 4.1.46
Version 4.1.45:
Version 4.1.44:
Version 4.1.43:
Version 4.1.40:
Version 4.1.38:
usage: wlt-gw-certificate [-h] -owner OWNER -gw GW [-suffix SUFFIX] [-tests {connection,uplink,downlink,stress}]
Gateway Certificate - CLI Tool to test Wiliot GWs
required arguments:
-owner OWNER Owner ID
-gw GW Gateway ID
optional arguments:
-suffix Allow for different suffixes after the GW ID in MQTT topics
-tests Pick specific tests to run
-update Update the firmware of the test board
-h, --help show this help message and exit
Plots the gain-current curve for a given bridge to help determine optimal configuration in terms of power consumption
usage: wlt-power-optimization -bridge_type BridgeType -dc DutyCycle -gw GW -rxtx_period RxTxPeriod
required arguments:
-bridge_type BRIDGE_TYPE The bridge type that will be analyzed
-dc DC Duty cycles to compare in the plot
-rxtx_period RXTX_PERIOD The rxtx periods in mili-sec corresponding to the duty cycles
example usage: wlt-power-optimization -bridge_type minew -dc 0.33 0.5 -rxtx_period 15 20
Uses USB Dev Board to sniff Wiliot BLE Packets
BLE Sniffer - CLI Tool to Sniff BLE Packets
optional arguments:
-h, --help show this help message and exit
required arguments:
-p P UART Port.
-c {37,38,39} channel
usage: wlt-sniffer [-h] -p P -c {37,38,39}
Uses USB Dev Board to send Wiliot BLE Packets
optional arguments:
-h, --help show this help message and exit
required arguments:
-p P USB UART Port
-packet PACKET packet
optional arguments:
-c C channel (if not specified packet will be sent on all BLE adv. channels (37/38/39))
-delay DELAY ms delay between packets (if not specified defaults to 20ms)
-dup DUP duplicates (defaults to 3)
-output OUTPUT output power (defaults to 8dBm)
-ts TS trigger by time stamp
usage: wlt-ble-sim [-h] -p P -packet PACKET [-c C] [-delay DELAY] [-dup DUP] [-output OUTPUT] [-ts TS]
Version 4.2.0:
Version 4.1.9:
Version 4.1.8:
Version 4.1.7:
Version 4.1.1:
Version 4.1.0:
Version 4.0.13:
Version 4.0.12:
Version 4.0.11:
Version 4.0.10:
Version 4.0.8:
Version 4.0.7:
Version 4.0.4:
Version 4.0.3:
Version 4.0.0:
The package previous content was published under the name 'wiliot' package. for more information please read 'wiliot' package's release notes
Python version 3.7 on Mac OS has stopped using the OS's version of SSL and started using Python's implementation instead. As a result, the CA certificates included in the OS are no longer usable. To avoid getting SSL related errors from the code when running under this setup you need to execute Install Certificates.command Python script. Typically you will find it under
/Applications/Python\ 3.7/Install\ Certificates.command
The default Python version on mac is 2.x. Since Wiliot package requires Python 3.x you should download Python3 (e.g. Python3.7) and make python 3 your default. There are many ways how to do it such as add python3 to your PATH (one possible solution https://www.educative.io/edpresso/how-to-add-python-to-the-path-variable-in-mac)
FAQs
A library for interacting with Wiliot's Deployment Tools
We found that wiliot-deployment-tools demonstrated a healthy version release cadence and project activity because the last version was released less than a year ago. It has 1 open source maintainer collaborating on the project.
Did you know?
Socket for GitHub automatically highlights issues in each pull request and monitors the health of all your open source dependencies. Discover the contents of your packages and block harmful activity before you install or update your dependencies.
Security News
Research
The Socket Research Team breaks down a malicious wrapper package that uses obfuscation to harvest credentials and exfiltrate sensitive data.
Research
Security News
Attackers used a malicious npm package typosquatting a popular ESLint plugin to steal sensitive data, execute commands, and exploit developer systems.
Security News
The Ultralytics' PyPI Package was compromised four times in one weekend through GitHub Actions cache poisoning and failure to rotate previously compromised API tokens.