A library to retrieve blood pressure measurements from the SilverCrest® SBM69 Bluetooth Blood Pressure Monitor
This project provides a library and a CLI to export blood pressure measurements from SilverCrest® SBM69 Bluetooth Blood Pressure Monitor devices.
Just clone the repo and then execute:
$ pip install sbm69
$ sbm69 [-h] [address]
For example:
$ sbm69 > john-doe-blood-pressure-`date +%F`.csv
The device requires a one-time pairing in order to provide access to its stored blood pressure measurements. Before the first connection attempt, perform the following:
Start a terminal and run bluetoothctl
.
In a second terminal issue the sbm69
command without any arguments.
Press the M
button on the SBM69 device.
In the second terminal you will see output similar to this:
Scanning for an SBM69 Device...
Device with address B8:B7:7D:XX:XX:XX found.
In the first terminal you will see output similar to this:
[CHG] Device B8:B7:7D:XX:XX:XX UUIDs: 00001800-0000-1000-8000-00805f9b34fb
[CHG] Device B8:B7:7D:XX:XX:XX UUIDs: 00001801-0000-1000-8000-00805f9b34fb
[CHG] Device B8:B7:7D:XX:XX:XX UUIDs: 0000180a-0000-1000-8000-00805f9b34fb
[CHG] Device B8:B7:7D:XX:XX:XX UUIDs: 00001810-0000-1000-8000-00805f9b34fb
[CHG] Device B8:B7:7D:XX:XX:XX ServicesResolved: yes
[CHG] Device B8:B7:7D:XX:XX:XX Trusted: yes
Request passkey
[agent] Enter passkey (number in 0-999999):
Enter the passkey displayed on the SBM69 device's display before it disappears.
sbm69
command.sbm69
command again.M
button of your SBM69 device.The device uses a protocol based on but not compliant to the Blood Pressure Profile HDP. It exposes the following BLE services and characteristics:
Service: Blood Pressure (00001810-0000-1000-8000-00805f9b34fb)
Characteristic: Blood Pressure Feature (00002a49-0000-1000-8000-00805f9b34fb), properties: read
Value: (0400)
Characteristic: Intermediate Cuff Pressure (00002a36-0000-1000-8000-00805f9b34fb), properties: notify
Descriptor: Client Characteristic Configuration (00002902-0000-1000-8000-00805f9b34fb)
Characteristic: Blood Pressure Measurement (00002a35-0000-1000-8000-00805f9b34fb), properties: indicate
Descriptor: Client Characteristic Configuration (00002902-0000-1000-8000-00805f9b34fb)
Value: 1eXXXXXXXXXXXXe70702190d3200XX00000000
Value: 1eXXXXXXXXXXXXe70702190d3300XX00000000
Value: 1eXXXXXXXXXXXXe70702190d3500XX00000400
Value: 1eXXXXXXXXXXXXe7070219170000XX00000000
Service: Device Information (0000180a-0000-1000-8000-00805f9b34fb)
Characteristic: PnP ID (00002a50-0000-1000-8000-00805f9b34fb), properties: read
Value: ()
Characteristic: Serial Number String (00002a25-0000-1000-8000-00805f9b34fb), properties: read
Value: XXXXXXXXXXXX (XXXXXXXXXXXXXXXXXXXXXXXX)
Characteristic: Software Revision String (00002a28-0000-1000-8000-00805f9b34fb), properties: read
Value: 2.0 (322e30)
Characteristic: Firmware Revision String (00002a26-0000-1000-8000-00805f9b34fb), properties: read
Value: 2.0 (322e30)
Characteristic: Hardware Revision String (00002a27-0000-1000-8000-00805f9b34fb), properties: read
Value: 7100 (37313030)
Characteristic: IEEE 11073-20601 Regulatory Cert. Data List (00002a2a-0000-1000-8000-00805f9b34fb), properties: read
Value: ()
Characteristic: Model Number String (00002a24-0000-1000-8000-00805f9b34fb), properties: read
Value: SBM69 (53424d3639)
Characteristic: Manufacturer Name String (00002a29-0000-1000-8000-00805f9b34fb), properties: read
Value: Hans Dinslage GmbH (48616e732044696e736c61676520476d6248)
Characteristic: System ID (00002a23-0000-1000-8000-00805f9b34fb), properties: read
Value: (0000000000000000)
Service: Generic Attribute Profile (00001801-0000-1000-8000-00805f9b34fb)
Characteristic: Service Changed (00002a05-0000-1000-8000-00805f9b34fb), properties: indicate
Descriptor: Client Characteristic Configuration (00002902-0000-1000-8000-00805f9b34fb)
The Blood Pressure Feature
characteristic seems to provide incorrect data. It
indicates that the device only supports 'Pulse Rate Range Detection Support',
which is not the case.
The Intermediate Cuff Pressure
characteristic is not usable because the device
does not activate Bluetooth during a measurement.
The Blood Pressure Measurement
characteristic is used for transferring the
blood pressure measurements stored in the device. When a user registers for
indications from it, the device immediately starts sending data. After all
records have been sent as indications, the device proceeds to turn off its
Bluetooth functionality, thus disconnecting the user.
The following ImHex pattern can be used to parse the data contained in each of the characteristic's notifications:
bitfield Flags {
blood_pressure_units: 1;
time_stamp: 1;
pulse_rate: 1;
user_id: 1;
measurement_status: 1;
vreserved_for_future_use: 3;
};
bitfield MeasurementStatus {
body_movement_detected: 1;
cuff_too_loose: 1;
irregular_pulse: 1;
pulse_rate_exceeds_lower_limit: 1;
pulse_rate_exceeds_upper_limit: 1;
improper_measurement_position: 1;
reserved_for_future_use: 10;
};
struct BloodPressureMeasurement {
le Flags flags;
if (flags.blood_pressure_units) {
le u16 systolic_kpa;
le u16 diastolic_kpa;
le u16 mean_arterial_pressure_kpa;
} else {
le u16 systolic_mmhg;
le u16 diastolic_mmhg;
le u16 mean_arterial_pressure_mmhg;
}
if (flags.time_stamp) {
le u16 year;
u8 month;
u8 day;
u8 hours;
u8 minutes;
u8 seconds;
}
if (flags.pulse_rate) {
le u16 pulse_rate;
}
if (flags.user_id) {
u8 user_id;
}
if (flags.measurement_status) {
le MeasurementStatus measurement_status;
}
};
BloodPressureMeasurement bpm @ 0x00;
Note that the medfloat16
fields from the HDP profile specification have been
replaced with uint16
fields.
Copyright © Petko Bordjukov, 2023
The program is available as open source under the terms of the GNU Affero General Public License v3 or later (AGPLv3+).
FAQs
A library to retrieve blood pressure measurements from the SilverCrest® SBM69 Bluetooth Blood Pressure Monitor
We found that sbm69 demonstrated a healthy version release cadence and project activity because the last version was released less than a year ago. It has 1 open source maintainer collaborating on the project.
Did you know?
Socket for GitHub automatically highlights issues in each pull request and monitors the health of all your open source dependencies. Discover the contents of your packages and block harmful activity before you install or update your dependencies.
Security News
vlt's new "reproduce" tool verifies npm packages against their source code, outperforming traditional provenance adoption in the JavaScript ecosystem.
Research
Security News
Socket researchers uncovered a malicious PyPI package exploiting Deezer’s API to enable coordinated music piracy through API abuse and C2 server control.
Research
The Socket Research Team discovered a malicious npm package, '@ton-wallet/create', stealing cryptocurrency wallet keys from developers and users in the TON ecosystem.